Door frame: KD Jambs & Header with
closer reinforcing sleeve. Prepped for
Steelcraft leaf. Base mounting clips
included
Threshold: Aluminum w/ anchors &
sealant. Includes weather-stripping
Weather-stripping
Hinges: 3 knuckle NRP
Necessary hardware bag for installation of
the above.
Window Framed Openings (optional): 2429 ;
3829 ; 3841; 5041; or 6441 sizes (glass nominally
daylight opening DLO w x h) Designed
to fit integrally within the wall system and to
displace the loads on walls and roof.
Partition Walls: (Optional): Made from
exterior wall panels. Span Width of
building max. May include optional
accessories such as doors, louvers, & windows.
Louvers: (Optional)- Integrally framed
louvers primed Neutral Tan (NT)
Fix Louver Vent (FLV)- Fixed blades
with bird screen. 3 sizes (16w x 24h ; 32w x
24h, 48w x42h)
Operable Louver Vent (OLV): Manually
operated linkage blades with bird screen. 3
sizes (16w x 24h ; 32w x 24h, 48w x42h)
Stamped Wall Louver. Louver
vents stamped in wall panel. Not for
insulated buildings. 1 size (16w x 18h)
Liner Panel: 26 ga. Corrugated Panels
Color: Polar White (PW)
Gutter (optional): 24 ga. construction.
Factory pre-painted colors same as eave trim
above.
Downspout: 3"x 4" Corrugated Steel 24
ga. color to match trim color (standard for
downspout is "A" elbows optional "B" elbows are
available.)
Flat Sidewall Panels: 3" 24 ga
concealed fastener 16" wide embossed with no
sculpture. These panels are used for flush
mounting exterior wall hung equipment such as air
conditioners or electrical equipment.
Color to match wall color. **Note** Flat
panels may not be used at corner panel
conditions.
Fascia sculpture closure (optional):
This part is used to flash off underside of
fascia where sculpture in wall panel occurs.
**Note** standard is wall cap that rests behind
fascia at top of wall panel. Sculpture
closures will eliminate wall cap.
Engineer Letter of Certification: 1
page stamped letter by an engineer of your state
based on your project specifications.
Engineer Stamped Calculations: Book
containing engineering backup data on a project
specific basis. Stamped by an engineer of your
state.
Door Leaves: Standard
2470, 3070, & 6070 Mortise or Cylinder prep.
Solid or 1/2 glass. Inactive leaves have
astragal prepped w/ flush bolts. Glass is wire
glass.
Door Handle: Cylinder or Mortise
type; Latchset or Lockset Lever
Door Closer: Optional
standard or hold open closers on all active leaves
Excluded
Items: (NOT BY PHOENIX)
Concrete foundation: We will provide
reactions for design of foundation by others
Base plate anchors / design. This should
be included by foundation engineer.
Base channel prepped for 3/8" anchor @ 16" O.C.
for easy attachment.
Are you a
Designer?
Download a
specification worksheet prepared
for fill in the blank entry. Format as
necessary to include Phoenix TL buildings in your
specifications.